Verified performance data for every ProLayers film: architectural window film, automotive window tint and paint protection film. Every number is shown with the test basis it was measured on.

ProLayers supplies 31 architectural films, 18 automotive window tint shades and 3 paint protection films. Window film data is measured to National Fenestration Rating Council (NFRC) guidelines on single-pane, nominal 1/4 inch (6 mm) clear glass, with infrared figures covering 780 to 2500 nm.

Architectural window film

Solar control, exterior, safety and security, decorative and specialty films for homes and commercial buildings. Sheet revision 8/1/2026.

ProductVLTVLR interiorVLR exteriorIRER*SIRR**Solar transmittanceSolar reflectanceSolar absorptanceTSERShading coefficientSHGCU-valueEmissivityUV rejectionGlare reduction
Architectural Films
Clarity IR Max 7572%8%8%76%94%35%25%40%54%53%0.460.920.64>99%21%
Clarity IR Max 4542%6%6%76%94%24%23%53%61%45%0.390.920.65>99%55%
Clarity IR Max 2522%5%5%76%94%17%21%62%65%41%0.350.930.66>99%77%
Nano Ceramic 7068%9%8%58%75%50%8%42%45%64%0.551.020.72>99%24%
Nano Ceramic 5053%10%12%66%66%40%11%49%44%65%0.561.050.89>99%40%
Nano Ceramic 3035%15%15%83%83%24%17%58%60%50%0.431.030.86>99%61%
Climate IQ 5052%25%22%66%79%35%26%41%56%51%0.440.770.37>99%42%
Skyline 3537%8%13%47%66%38%12%50%47%62%0.531.010.81>99%58%
Skyline 2527%14%27%61%81%26%25%50%60%47%0.400.970.74>99%70%
Skyline 1515%21%47%74%91%13%40%47%73%31%0.270.950.69>99%84%
Skyline 58%15%55%77%94%9%45%46%78%26%0.220.940.69>99%91%
Harmony DR 3738%12%18%52%64%35%20%45%52%56%0.480.990.72>99%57%
Harmony DR 2728%18%31%64%80%25%32%43%64%42%0.360.970.71>99%68%
Harmony DR 1717%13%37%70%89%18%38%44%71%34%0.290.970.71>99%81%
Harmony DR 76%11%50%23%92%11%53%36%80%23%0.200.960.70>99%93%
Soft Tone 2419%17%29%67%86%20%30%51%66%40%0.340.960.72>99%78%
Soft Tone 109%12%19%70%83%15%31%54%69%36%0.310.950.70>99%89%
Eco Silver 2019%56%55%78%94%13%45%42%76%28%0.240.880.58>99%79%
Exterior Films
X-Clear 70—————————————>99%—
X-Eco Silver 1516%58%57%86%94%11%46%43%77%27%0.230.950.70>99%82%
X-Hybrid DR 1514%17%42%79%91%13%48%39%75%29%0.251.020.72>99%84%
X-Safety 788%8%8%N/AN/AN/AN/AN/A19%94%0.81N/AN/A>99%1%
Safety & Security Films
Security 14 Clear87%9%9%N/AN/AN/AN/AN/A20%93%0.80N/AN/A>99%3%
Security 8 Clear86%9%9%N/AN/AN/AN/AN/A21%92%0.79N/AN/A>99%3%
Security 8 Silver17%58%56%78%95%12%45%43%77%27%0.230.880.58>99%81%
Safety 4 Clear87%9%9%N/AN/AN/AN/AN/A20%93%0.80N/AN/A>99%2%
AG 6 Clear87%10%10%N/AN/A76%9%15%19%94%0.811.020.84>99%3%
Decorative Films
Frost Layer75%25%22%N/AN/A69%20%11%27%98%0.84N/AN/A>99%17%
White Out Layer14%84%87%N/AN/A18%66%16%77%27%0.23N/AN/A>99%84%
Black Out Layers0%13%8%N/AN/A0%11%89%71%34%0.29N/AN/A>99%100%
Specialty Films
Poly Layers88%9%9%N/AN/A77%8%15%19%94%0.811.020.84>99%1%

Test basis. NFRC guidelines, single-pane nominal 1/4 inch (6 mm) clear glass. *IRER (infrared energy rejection) measures the total heat experienced from solar infrared radiation, 780 to 2500 nm, including both absorbed and re-radiated energy. **SIRR (solar infrared rejection) measures the proportion of solar infrared radiation, 780 to 2500 nm, that is not directly transmitted through the glass. VLT = visible light transmittance. VLR = visible light reflectance. TSER = total solar energy rejected. SHGC = solar heat gain coefficient. N/A = not available at this time. A dash means the value is not yet published.

Safety and security film strength

ProductTensile strength (avg. MD/TD)Break strength (per inch width)Peel strength
AG 6 Clear25,000 PSI150 lbs/in3 to 4 lbs/in
Safety 4 Clear25,000 PSI100 lbs/in5 to 6 lbs/in
X-Safety 725,000 PSI175 lbs/in5 to 6 lbs/in
Security 8 Clear25,000 PSI200 lbs/in5 to 6 lbs/in
Security 8 Silver25,000 PSI200 lbs/in5 to 6 lbs/in
Security 14 Clear25,000 PSI325 lbs/in5 to 6 lbs/in

Tensile strength is 25,000 PSI average (machine and transverse direction) across the listed safety film constructions. Break strength ranges from 100 to 325 lbs per inch of width depending on construction. Peel strength ranges from 3 to 6 lbs per inch depending on construction and adhesive system.

Automotive window tint

Three families: V16 Ceramic IR MAX (highest heat rejection), V10 Ceramic IR BLK (ceramic infrared control) and V6 Comfort BLK (glare and UV control). The number after each name is the shade. Sheet revision 10/7/2026.

Product and shadeVLTVisible light reflectionTSERGlare reductionIRERUV rejectionIR rejection at 1025 nm
V16 Ceramic IR MAX
V16 Ceramic IR MAX 55%7%72%95%70%99%96%
V16 Ceramic IR MAX 1518%7%69%82%70%99%96%
V16 Ceramic IR MAX 3533%7%63%63%70%99%96%
V16 Ceramic IR MAX 5051%7%58%45%70%99%96%
V16 Ceramic IR MAX 7070%8%52%24%68%99%92%
V10 Ceramic IR BLK
V10 Ceramic IR BLK 55%6%66%95%58%99%78%
V10 Ceramic IR BLK 1517%6%64%82%58%99%78%
V10 Ceramic IR BLK 2022%6%62%78%58%99%78%
V10 Ceramic IR BLK 3535%6%58%62%58%99%78%
V10 Ceramic IR BLK 4544%7%53%51%58%99%78%
V10 Ceramic IR BLK 5555%7%51%40%58%99%78%
V10 Ceramic IR BLK 7070%8%48%23%64%99%85%
V6 Comfort BLK
V6 Comfort BLK 55%6%43%95%11%99%13%
V6 Comfort BLK 1515%6%41%82%11%99%13%
V6 Comfort BLK 2021%6%40%78%11%99%13%
V6 Comfort BLK 3230%6%37%65%11%99%13%
V6 Comfort BLK 3535%6%36%62%11%99%13%
V6 Comfort BLK 4344%6%33%51%11%99%13%

Test basis. NFRC guidelines, single-pane nominal 1/4 inch (6 mm) clear glass. IRER measures the total heat experienced from solar infrared radiation, 780 to 2500 nm, including both absorbed and re-radiated energy. IR rejection at 1025 nm is a single-wavelength figure and reads higher than IRER; compare films on IRER and TSER.

Paint protection film

Clear thermoplastic polyurethane (TPU) film with a protective top coat and pressure-sensitive adhesive, for vehicle paint.

PropertyV6 Core LayersV10 Reactive LayersV16 Ceramic IR MAX PPF
Overall thickness (without liner)187 µm192 µm192 µm
Top coat7 µm7 µm7 µm
TPU film150 µm155 µm155 µm
Pressure-sensitive adhesive30 µm30 µm30 µm
Release liner75 µm75 µm75 µm
Tensile strength (ASTM D882)16 MPa18 MPa20 MPa
Elongation at break (ASTM D882)> 250%> 300%> 300%
Gloss at 60°> 90 GU> 90 GU> 90 GU
Stone chip resistance (Gravelometer, SAE J400)PassPassPass

Test results, all three films

TestTest conditionResult
Peel strength
Initial peel20 min at room temperature> 400 N/m
Normal state72 h at room temperature> 400 N/m
After water immersion400 h at 40°C> 400 N/m
After accelerated weathering2000 h QUV> 400 N/m
Aging
Heat aging16 days at 80°CNo detrimental effect
Water immersion400 h at 40°CNo detrimental effect
Accelerated weathering2000 h QUVNo detrimental effect
Boiling water5 minNo detrimental effect
Solvent resistance
Water and soap spotting24 hNo detrimental effect
Acid spotting24 hNo detrimental effect
Isopropyl alcohol24 hNo detrimental effect
Hexane / toluene24 hNo detrimental effect
Motor oil24 hNo detrimental effect

Values shown are typical values supplied by the manufacturer and are not intended for specification purposes. Data sheet revision 1.0. Refer to the installation guide and warranty documentation for full details.

What the numbers mean

What is VLT?
Visible light transmittance is the percentage of visible light that passes through the glass and film. A lower number means a darker film: 5% is very dark, 70% is nearly clear.
What is TSER?
Total solar energy rejected is the percentage of the sun's total energy (visible light, infrared and ultraviolet) that the glass and film stop from entering. It is the best single number for comparing how much heat a film blocks.
What is the difference between IRER and SIRR?
Both cover solar infrared from 780 to 2500 nm. IRER counts the total infrared heat you experience, including energy the film absorbs and re-radiates inward. SIRR counts only the infrared that is not directly transmitted through the glass, so SIRR is always the higher figure.
Why is IR rejection at 1025 nm higher than IRER?
It is measured at a single wavelength where ceramic films perform best. IRER covers the full solar infrared range, so it is the more realistic figure.
What are SHGC and shading coefficient?
Solar heat gain coefficient is the fraction of solar energy that gets through, from 0 to 1. Lower means less heat. Shading coefficient is the same idea expressed relative to clear 1/8 inch glass.
What are U-value and emissivity?
U-value measures how readily heat passes through the glass because of a temperature difference; lower insulates better. Emissivity measures how much heat the surface radiates; lower emissivity keeps more heat on the side it came from.
What glass were these films tested on?
Single-pane, nominal 1/4 inch (6 mm) clear glass, following NFRC guidelines. Results on tinted, low-E or double-pane glass will differ.

Reported values are based on representative product samples and are subject to normal manufacturing variation. Actual performance may vary with glass type and glass properties. Calculated values may differ slightly between similar products due to averaging and rounding.

Need a data sheet or a recommendation?

Call or text 844-9-LAYERS or email info@prolayers.com.