Performance data

Compare film performance

Sort every ProLayers film by the number that matters to your job. Select a column heading to sort, select it again to reverse. Star films to compare them side by side.

VLT range (%) to

Glass type: 1/4 in (6 mm) single-pane clear · NFRC guidelines

Architectural window film performance data. Select a column heading to sort.
Clarity IR Max 75Solar control54%72%8%8%76%94%35%25%40%53%0.460.920.64>99%21%
Clarity IR Max 45Solar control61%42%6%6%76%94%24%23%53%45%0.390.920.65>99%55%
Clarity IR Max 25Solar control65%22%5%5%76%94%17%21%62%41%0.350.930.66>99%77%
Nano Ceramic 70Solar control45%68%9%8%58%75%50%8%42%64%0.551.020.72>99%24%
Nano Ceramic 50Solar control44%53%10%12%66%66%40%11%49%65%0.561.050.89>99%40%
Nano Ceramic 30Solar control60%35%15%15%83%83%24%17%58%50%0.431.030.86>99%61%
Climate IQ 50Solar control56%52%25%22%66%79%35%26%41%51%0.440.770.37>99%42%
Skyline 35Solar control47%37%8%13%47%66%38%12%50%62%0.531.010.81>99%58%
Skyline 25Solar control60%27%14%27%61%81%26%25%50%47%0.400.970.74>99%70%
Skyline 15Solar control73%15%21%47%74%91%13%40%47%31%0.270.950.69>99%84%
Skyline 5Solar control78%8%15%55%77%94%9%45%46%26%0.220.940.69>99%91%
Harmony DR 37Solar control52%38%12%18%52%64%35%20%45%56%0.480.990.72>99%57%
Harmony DR 27Solar control64%28%18%31%64%80%25%32%43%42%0.360.970.71>99%68%
Harmony DR 17Solar control71%17%13%37%70%89%18%38%44%34%0.290.970.71>99%81%
Harmony DR 7Solar control80%6%11%50%23%92%11%53%36%23%0.200.960.70>99%93%
Soft Tone 24Solar control66%19%17%29%67%86%20%30%51%40%0.340.960.72>99%78%
Soft Tone 10Solar control69%9%12%19%70%83%15%31%54%36%0.310.950.70>99%89%
Eco Silver 20Solar control76%19%56%55%78%94%13%45%42%28%0.240.880.58>99%79%
X-Clear 70Exterior—————————————>99%—
X-Eco Silver 15Exterior77%16%58%57%86%94%11%46%43%27%0.230.950.70>99%82%
X-Hybrid DR 15Exterior75%14%17%42%79%91%13%48%39%29%0.251.020.72>99%84%
X-Safety 7Exterior19%88%8%8%N/AN/AN/AN/AN/A94%0.81N/AN/A>99%1%
Security 14 ClearSafety & security20%87%9%9%N/AN/AN/AN/AN/A93%0.80N/AN/A>99%3%
Security 8 ClearSafety & security21%86%9%9%N/AN/AN/AN/AN/A92%0.79N/AN/A>99%3%
Security 8 SilverSafety & security77%17%58%56%78%95%12%45%43%27%0.230.880.58>99%81%
Safety 4 ClearSafety & security20%87%9%9%N/AN/AN/AN/AN/A93%0.80N/AN/A>99%2%
AG 6 ClearSafety & security19%87%10%10%N/AN/A76%9%15%94%0.811.020.84>99%3%
Frost LayerDecorative27%75%25%22%N/AN/A69%20%11%98%0.84N/AN/A>99%17%
White Out LayerDecorative77%14%84%87%N/AN/A18%66%16%27%0.23N/AN/A>99%84%
Black Out LayersDecorative71%0%13%8%N/AN/A0%11%89%34%0.29N/AN/A>99%100%
Poly LayersSpecialty19%88%9%9%N/AN/A77%8%15%94%0.811.020.84>99%1%

Key terms. TSER = total solar energy rejected, the best single number for heat. VLT = visible light transmittance; lower is darker. IRER = infrared energy rejection, 780 to 2500 nm. SHGC = solar heat gain coefficient; lower means less heat. IR at 1025 nm is a single-wavelength figure and reads higher than IRER. N/A = not available at this time. A dash means the value is not yet published.

Performance values captured using NFRC guidelines and calculated for single-pane, nominal 1/4" (6mm) clear glass. Values are based on representative product samples and are subject to normal manufacturing variation. Actual performance may vary by glass type and properties. See ProLayers technical data for additional information.